7. APOLLO SMART TRANSMITTER BATTERY CHANGE
If the battery in the Apollo Smart Transmitter needs to be changed the display will provide advance warning
by showing the 'TANK LOW BATTERY' text below the bar-graph.
-
Remove the Apollo Smart Transmitter from the tank and take it to a safe location
-
The battery can be accessed by removing the 4 self-tapping screws from the base of the unit.
-
Remove the old battery noting the orientation ('+' mark facing outwards), and replace it with a new
battery, 3V CR2450
-
Re-assemble, ensuring the O-ring is undamaged and secured in position.
-
Re-locate the transmitter on the tank.
There is no need to re-synchronise the transmitter with the monitor when the transmitter battery is
changed.
Disposal
The crossed out dustbin on the packaging indicates that this product and its battery shall not be treated as
household waste. Proper disposal will help prevent potentially negative consequences for the environment
and human health. For more detailed information about recycling of this product or battery, please contact
your local Recycling centre or the shop where you purchased the product.
8. TROUBLESHOOTING
If the Apollo Smart Monitor does not receive or cannot understand the
RF signal from the Apollo Smart Transmitter an error message will be
displayed on the Apollo Smart Monitor. The error message appears as
an alternating screen showing 'Err' and 'E:0?' where ? is a number.
Error codes are listed on a label on the rear of your Apollo Smart
Monitor.
Error
Description
E01
Received reading is inconsistent
E02
Received Reading not received after 6 hours
E03
Received Reading received but void
E04
Received Reading greater than tank height
E05
Contact Vendor
E06
Contact Vendor
Suggested remedy
• Check the transmitter is vertical on the tank.
• Check positioning of the transmitter (ensure the transmitter is not too close
to the tank sides or internal obstructions).
• Ensure that the transmitter is not too tightly attached to the tank.
• Ensure that the tank is not overfilled and that the bottom of the transmitter
is clean.
• Check the transmitter is within range of the monitor. Try and relocate the
monitor to a position that is nearer a window, remember that the transmitter
communicates with the monitor by use of an FM signal and moving the
monitor from possible metal obstructions can improve the signal
• Check that there is no metal object such as a van, truck or that there is
nothing in the fabric of the building, that may deflect the signal. Wait for an
hour to see if you have a new reading.
• Ensure the monitor is not too close or obstructed by other electrical
appliances.
• Check positioning of the transmitter (ensure the transmitter is not too close
to the tank sides or internal obstructions).
• Ensure that the transmitter is not too tightly attached to the tank.
• Ensure that the tank is not overfilled i.e. there is a minimum of 120mm free
space between the transmitter and oil level.
• Ensure the bottom of sensor is clean.
• If a bund tank, ensure the transmitter is located on the inner tank.
• Check the tank height and ensure this information is correct on the monitor,
press the r and s keys together to view your tank configuration. If
height is incorrect, enter the setup mode by pressing SETUP for 3 secs, press
ENTER until you reach screen 5 and adjust the height by using r and s
keys. Press ENTER to save. Press SETUP to exit Setup mode. Await 3 hours for
updated readings.
• Check the transmitter is vertical and positioning of the transmitter (ensure
the transmitter is not too close to the tank sides or internal obstructions
• This is a hardware fault and requires contact with the vendor
• This is a hardware fault and requires contact with the vendor