Danish Interpretation Systems
6 Technical Specifications
6.1
Technical specifications
Sound quality ..... 20 bit audio @ 32 kHz sampling frequency
Digital Section
Output signal type ........... ground lifting transformer balanced
Analog Section
Nominal output level: ............................ 0 dBm at nominal input
Max. Output level: ..................................................................... 15 dBm
Frequency response ............................................................ 50-16kHz
Signal to noise ratio: ............................................................ >85 dBA
Total harmonic distortion: ................................................... < 0.1%
Power requirement ........................................................... 24-48 V DC
General
Power consumption .................................................... 2W maximum
Power supplied from .................. CU 61xx / EX 6010 / PS 6000
Temperature to guarantee specified performance
.................................. 5 Deg C. to 40 Deg C. (35 to 80 % humidity)
6.2
Connection Details
The DCS 6000 system uses Cat5e, Cat6 or Cat7 F/UTP
DCS-LAN Chain
or U/FTP cables with screened RJ45 connectors.
EIA 568-B wiring shall be used.
Important: The names of Cat5/6/7 cable type have
changed.
Old name
FTP
STP
UTP
Important: Use only F/UTP or U/FTP (screened) cables
and screened RJ45 connectors and not U/UTP cable, which
are unscreened.
How to wire a Cat5e (EIA 568-B) cable to a RJ45 con.:
12
New name
F/UTP
U/FTP
U/UTP
USER MANUAL AO 6004 REV B.DOCX
............................. -20 Deg C. to 60 Deg C. (10 to 80 % humidity)
Storage temperature
Weight ............................................................................................. 0.84 kg
Dimensions (W x H x D) ......... 180 (205) x 38 x 120 (120) mm
Dimensions in bracket are including brackets
DCS-LAN network ......................................................... 2 pieces RJ45
Connectors
Analog outputs connectors ............. 4 - XLR3 male connectors
By using SW 6000 the user can control the following
Remote Control commands in/out
settings in the AO 6004 through the CU 6105/CU6110.
* .................................... Channel number for each output channel
* ....................................................... Volume setting for each channel
* The settings can only be read or controlled from the SW
6000.
Specifications are subject to change without notice.
Pin
Function
1
In-going +
ORG/WHT
2
In-going -
ORG
3
+48V
GRN/WHT
4
0V
BLU
5
0V
BLU/WHT
6
+48V
GRN
7
Outgoing -
BRN/WHT
8
Outgoing +
BRN
Important: If other color codes are used then the four pairs
are connected as follows:
Pair 2:
Pin 1 & 2
Pair 3:
Pin 3 & 6
Pair 1:
Pin 4 & 5
Pair 4:
Pin 7 & 8
User Manual
Connector #1
Connector #2
ORG/WHT
ORG
GRN/WHT
BLU
BLU/WHT
GRN
BRN/WHT