DANLERS CEFL RFD250W Notas de instalación - Página 2

Navegue en línea o descargue pdf Notas de instalación para Regulador de intensidad DANLERS CEFL RFD250W. DANLERS CEFL RFD250W 2 páginas. Radio receiver dimmers

Installation procedure
1. Please read these notes carefully before commencing work.
In case of doubt please consult a qualified electrician.
Make sure the power is isolated from the circuit.
2. The radio receiver dimmer should be connected as:
L
Live
N
Neutral
V
Variable dimmed output
3.Typical wiring diagrams and mounting details are shown below.
4. EXRFD250W: unit should be fixed using ONLy the pre-drilled
mounting holes and 6-12mm diameter circular cables . If IP65 rating is
compromised, water ingress may occur, therefore you must carefully
drill through the drain-hole guide, on lower face of box with 4mm drill,
to max depth of 5mm, achieving IP54.
5. Once the wiring has been completed and verified, switch on the supply
and program the radio receiver dimmer to the appropriate senders.
Installation diagrams
WACE RFD250W, CEFL RFD250W
CEVO RFD500W, CERF D500W GT
Wiring diagram
V
L
L
optional wall switch
for overriding off
N
dimmable
radio
load
receiver
230 VAC
dimmer
N
CEFL RFD250W
mounting details
Springs closed
Springs opened out
Cut-out hole
63 or 64mm (2.5") diameter
EXRF D250W
Wiring diagram
EXRF D250W
L N V
L
dimmable
230 VAC
load
N
isolation
switch
Programming procedure
If you have a pre-programmed radio receiver dimmer please do
not attempt to reprogram it.
Each radio receiver dimmer can be programmed to respond to up to
15 senders as outlined below.
To assign a slave sender please refer to the installation notes received
with the slave sender.
CEFL RFD250W and WACE RFD250W have a single programming
hole, other units also have a smaller LED hole.
WARNING: Do not probe the smaller LED hole.
Needed: A small screwdriver to 'Press' the internal programming
button of the radio receiver.
Notes:
'Quick Press' - less than half a second, 'Wait Press' - until
next step is completed. To 'Quick Press' or 'Wait Press' the
manual sender use either the up or down button.
Ensure the radio receiver dimmer is powered.
WARNING: EXRF D250W terminals will be live during programming.
WARNING: If a load is connected during programming it will be
switched on when the LED is on.
To assign a Manual Sender
1 'Quick Press' the radio receiver LED switches on.
2 'Quick Press' the manual sender - LED flashes off twice.
To assign more senders repeat step 2
3 'Quick Press' the radio receiver LED switches off.
To de-assign a Manual Sender
1 'Quick Press' the radio receiver, LED switches on.
2 'Quick Press' the manual sender - LED flashes off twice.
To de-assign more senders repeat step 2
3 'Quick Press' the radio receiver LED switches off.
To de-assign all Senders
1 'Quick Press' the radio receiver, LED switches on.
2 'Wait Press' the radio receiver until LED flashes off five times.
3 Wait for 5 seconds, LED switches off.