ConSenses Accelerometer BA Series Manual de instrucciones de montaje - Página 7
Navegue en línea o descargue pdf Manual de instrucciones de montaje para Equipamiento industrial ConSenses Accelerometer BA Series. ConSenses Accelerometer BA Series 14 páginas.
limit, the over-range output (black, 0...5 V) signals for 0.5 ms that the measuring range has been exceeded.
The MEMS sensor then checks whether operation is within the measuring range limits. In the figure, this is
not the case again until a few 0.5 ms cycles later, whereupon the sensor registers the correct values again
within a 0.5 ms cycle.
When using the product, please consider the
Maximum load limits
▪
Safety factors from special safety regulations (e.g., EX areas, regulations for personal and plant pro-
▪
tection)
Environmental conditions.
▪
Also observe the following safety instructions and installation guidelines.
Accelerometer Assembly Instructions
Page 3