Specifications
Surge Suppression:
Extreme Voltage Shutdown
Voltage:
Common-Mode Noise Dissipation:
Transverse-Mode Noise
Dissipation:
Input Current Maximum Capacity:
Ultra-Linear Noise-Dissipation
System AC Power Outlet Banks:
Number of AC Outlets:
Power Consumption:
Dimensions:
Weight:
14
Non-sacrificial (nothing to damage with repeated 6000V/3000A
input surge tests, which is the maximum that can survive through a
building's AC electrical panel).
270VAC (will activate the main high-current relay to open within less
than 0.25 second; automatically resets once the incoming power is
within a safe range).
In excess of 30dB from 20kHz to 100MHz, linearized for dynamic
(rising) line impedance with frequency (source) and 10 to 50 ohm
load, system current dependent.
In excess of 24dB from 3kHz to 1GHz, linearized for dynamic
(rising) line impedance with frequency (source) and 10 to 50
ohm load, system current dependent.
16 amps RMS (total).
4 Isolated groups - total (bank 2 – outlets 5 and 6, or outlets 7
and 8) bank 3 outlets 9 and 10 or outlets 11 and 12).
12 (4 High Current/Transient Power Correction; 8 Ultra-Linear
Noise Dissipation System Power).
Typically, less than 0.25 amps at 230VAC input, or with the power
correction switched to Standby setting.
(This is dependent on a reactive vector load. For more info, see "Operation
and Continuous Use: Rear-Panel Power Correction Switch – Niagara
5000EU current draw. " )
445mm W x 133mm H x 437mm D (3-RU rack-mounting ears, optional)
18kg.