This specification is a technical document that certifies the DanVex AD-10000 dehumidifier
parameters and characteristics.

Purpose

DanVex AD-10000 (in short AD-10000) is designed for efficient air dehumidification with the air
humidity up to 100%, at the temperature from –20ºС to +40ºС with minimum energy
consumption. It can be used either as an independent unit for installation inside and outside of
premises where air humidity control is required or along with an air treatment system.
Operation principal
The main dehumidifier part is a rotor having a cellular structure made from fibrous ceramic
material and SelicaGel. The rotor is divided into two zones by a sealing device: one for
dehumidification, another for regeneration.
Thus, the dehumidifier works with two air flows. The volume of the dehumidified air is bigger. The
air flow of a smaller volume is used for moisture removal from the dehumidifier rotor. The rotor is
subject to the action of different oppositely directed air flows by sectors. The air flow to be
dehumidified (PROCESS AIR) passes through the biggest sector. The moisture from the air is
trapped (adsorbed) by the rotor material. The air leaves the rotor in dehumidified condition (DRY
AIR) and is directed to a certain part of the building or a technological process where
dehumidified air or a certain air humidity levels are required. Since the rotor rotates slowly the
incoming air always contacts with the rotor active part, thus a continuous dehumidification
process is assured.
The air flow used for the rotor regeneration is called regeneration air (REGENERATION AIR). It is
о
heated up to 140 С and when passing through a small sector it removes the moisture trapped by
the rotor material. The moisture is removed from the rotor in the form of humid air (MOIST AIR)
which is discharged outside the dehumidified loop
Process air
Process air fan
Filter
Moist air
·
The air to be dehumidified passes through the rotor. Water molecules are absorbed by the rotor.
·
The rotor is reactivated by another air flow preheated to 140 C. The moisture is removed from the room
in the form of moist air.
www.danvex.fi
R
Adsorption rotor
Rotor motor
Pic.1. Dehumidifier air flows diagram
Dry air
Regeneration air fan
Heater
о
4
Filter
Regeneration air