when the Meter is turned off.
Button
SELECT
Disables automatic power-off function. Display shows PoFF until the
button is released.
ENTER
Disable the "beep" function.
AUTOMATIC POWER-OFF (SLEEP MODE)
The Meter has automatic power-off function (sleep mode), which conserves
battery power if there is no function change or button press for ten minutes.
The Meter comes out of Sleep mode when a key is pressed or when the rotary
switch is changed.
To disable Sleep mode, hold down the SELECT button while turning the Meter on.
Sleep mode is always disabled in the 'Insulation Test' mode, or if the auto power-
off feature has been disabled by pressing SELECT when turning the Meter on.

HOLD FUNCTION

Press the HOLD button to freeze the displayed value. Press again to release the
display.

RELATIVE MEASUREMENT

Show the difference between the actual value and the relative base.
Press the REL button to enter relative measurement and the Meter will record the
initial value when pressing the key.
Displayed value = Actual value - Initial value.
Press the REL button again to exit relative measurement.
Press the SELECT button to view Initial value, when the Initial value is invalid the
display will read ----.

INSULATION TEST LOCK

In Insulation test mode, press the TEST button to perform an insulation test until
the button is released. When the button is released, the screen will display the
"Hold" sign.
Press the LOCK button, then the screen will display the "Lock" sign.
Press the TEST button and the Meter will perform an insulation test until you press
the TEST button again.
Lock function is invalid when the timer function is selected.

STORING TEST DATA

Press the MEMO button so that the meter enters HOLD status automatically.
The LCD screen will display "MEMO" and the memory code on the secondary
display.
Press
/
button to change the code, press enter to save the data in the preferred
memory code and the screen will display "SAVE".
Function
7