The VortSentry HS system should be inspected at regular intervals
and maintained when necessary to ensure optimum performance.
The rate at which the system collects pollutants will depend more
heavily on site activities than the size of the unit, i.e., unstable
soils or heavy winter sanding will cause the treatment chamber to
fill more quickly, but regular sweeping will slow accumulation.
Inspection
Inspection is the key to effective maintenance and is easily
performed. Pollutant deposition and transport may vary from
year to year and regular inspections will help ensure that the
system is cleaned out at the appropriate time. At a minimum,
inspections should be performed twice per year (i.e. spring and
fall) however more frequent inspections may be necessary in
equipment washdown areas and in climates where winter sanding
operations may lead to rapid accumulations of a large volume
of sediment. It is useful and often required as part of a permit
to keep a record of each inspection. A simple inspection and
maintenance log form for doing so is available for download at
www.contechstormwater.com.
The VortSentry HS should be cleaned when the sediment has
accumulated to a depth of two feet in the treatment chamber.
This determination can be made by taking two measurements
with a stadia rod or similar measuring device; one measurement
from the manhole opening to the top of the sediment pile and
the other from the manhole opening to the water surface. If the
difference between these measurements is less than the distance
given in Table 1, the VortSentry HS should be maintained to
ensure effective treatment.
Diameter
VortSentry HS
Model
in
HS36
36
HS48
48
HS60
60
HS72
72
HS84
84
HS96
96
Table 1: VortSentry HS Maintenance Indicators and Sediment Storage Capacities.
Distance Between
Water Surface and
Top of Storage
Sump
m
ft
m
0.9
3.6
1.1
1.2
4.7
1.4
1.5
6
1.8
1.8
7.1
2.2
2.1
8.4
2.6
2.4
9.5
2.9
Cleaning
Cleaning of the VortSentry HS should be done during dry weather
conditions when no flow is entering the system. Cleanout of the
VortSentry HS with a vacuum truck is generally the most effective
and convenient method of excavating pollutants from the system.
Simply remove the manhole cover and insert the vacuum hose
into the sump. All pollutants can be removed from this one access
point from the surface with no requirements for Confined Space
Entry.
In installations where the risk of petroleum spills is small, liquid
contaminants may not accumulate as quickly as sediment.
However, an oil or gasoline spill should be cleaned out
immediately. Motor oil and other hydrocarbons that accumulate
on a more routine basis should be removed when an appreciable
layer has been captured. To remove these pollutants, it may be
preferable to use adsorbent pads, which solidify the oils. These
are usually much easier to remove from the unit individually, and
less expensive to dispose than the oil/water emulsion that may be
created by vacuuming the oily layer. Floating trash can be netted
out if you wish to separate it from the other pollutants.
Manhole covers should be securely seated following cleaning
activities to prevent leakage of runoff into the system from above
and also to ensure proper safety precautions. If anyone physically
enters the unit, Confined Space Entry procedures need to be
followed.
Disposal of all material removed from the VortSentry HS should
be done is accordance with local regulations. In many locations,
disposal of evacuated sediments may be handled in the same
manner as disposal of sediments removed from catch basins or
deep sump manholes. Check your local regulations for specific
requirements on disposal.
Sediment Storage
Oil Spill Storage
yd
m
gal
3
3
0.5
0.4
83
0.9
0.7
158
1.5
1.1
258
2.1
1.6
372
2.9
2.2
649
3.7
2.8
845
liter
314
598
978
1409
2458
3199