COMBUSTION AIR SYSTEM INSTALLATION
3. Connect the supplied 4" aluminum flex tubing to the end of the
dryer vent and secure using aluminum tape or screws.
4a. If the dryer vent is mounted above the height of the base of the
firebox, let the open end of the aluminum tube hang uncon-
nected, near the floor.
DO NOT CONNECT OPEN END TO THE FIREPLACE. See FIG 13
4b. If the dryer vent is mounted on an exterior wall, and is located
below the height of the fireplace base, then connect the alumi-
num tube to the side-mount air manifold on the firebox. FIG 14.
WARNING: COMBUSTION AIR SUPPLY DUCTS SHOULD NEVER
TERMINATE IN ATTIC SPACES
FIG 13.
Do not connect free
end of aluminum flex
tubing to fireplace if
penetration to the
exterior is above
fireplace base
FIG 14.
Aluminum tubing should only be connected to
fireplace if dryer vent is below fireplace base
DO NOT CONNECT aluminum duct to firebox if
vent opening is above fireplace base!
FIG 11. combustion air from chase
Aluminum duct should remain unconnected near
the floor below fireplace opening
14
4" Metal Duct