Addonics Technologies AD5SAPM Manual del usuario - Página 2
Navegue en línea o descargue pdf Manual del usuario para Hardware informático Addonics Technologies AD5SAPM. Addonics Technologies AD5SAPM 2 páginas. 5x1 sata port multiplier
4-Pin Floppy Power Connector
Host SATA Port
Port 2
Port 3
Port 4
Port 5
Note:
When the internal port multiplier (PM) is connected to a SATA Host
controller with SiI3124 or SiI3132 chip, in the RAID BIOS of the host controller,
you will only see one drive and that is the drive connected to port 1 on the
hardware PM.
All the SATA drives connected to the PM will show in the SATARAID5 Array
Manager.
1.
Mount the internal SATA Port Multiplier onto the PCI bracket of any
standard desktop or low profile system.
2.
Attach the SATA hard drives (up to 5) to ports 1-5 on the Port Multiplier
using SATA cables.
3.
Attach a 4-pin floppy power cable from the power supply unit to the
Port Multiplier power connecter.
4.
Connect a SATA cable to the Host SATA port of the Port Multiplier then
to the SATA port of the raid controller.
CONTACT US
www.addonics.com
Phone:
Fax:
Email:
Port 1
Port 1 - 5
408-573-8580
408-573-8588
http://www.addonics.com/sales/query/
+
P
S
0
GND
LED KEY
0-4 Power and Drive Activity LED
H
Host Device LED
P
Power LED
S
System Ready LED
1
2
3
4
H