Aplisens SGE-25.Modbus Manual del usuario - Página 9

Navegue en línea o descargue pdf Manual del usuario para Instrumentos de medida Aplisens SGE-25.Modbus. Aplisens SGE-25.Modbus 20 páginas. Smart level probes

6.

INSTALLATION

6.1. General recommendation

The probe can be hung on the power cable, e.g. by using from the Aplisens SG cable hanger (item 1
in fig. 1). In the event of frequent removal of the probe or when there is a risk of catching on protruding
elements during pulling up, it is recommended to hang the probe on a steel cord using the carrying eye
(item 2 in Fig. 1.). The probes are immersed in the medium to be measured. A special cable extends
above the level of the medium and can be connected directly to probe or to a junction box. If the probe
is to be placed in the current or in an area of turbulence, it should be installed in a protective tube.
Figure 1. Mounting brackets for probes.
Do not clean or touch the diaphragm with hard or sharp objects. Hang the probe with the additional
Teflon coating on the cable on the suspension cable or on the inner cable (do not grab the Teflon).
Remove
the SGE-25S.Modbus type probe is inserted into the medium to be measured.
During installation protect the probe from mechanical impacts
Figure 2. Diaphragm cover for SGE-25S.Modbus probe.
Revision 01.A.001/2021.09
the
protective
cap
from
the
probe's
EN.IO.SGE.25.MODBUS
separator
immediately
before
9