APLOS R0-5050 Manual de instrucciones - Página 4
Navegue en línea o descargue pdf Manual de instrucciones para Sistemas de filtración de agua APLOS R0-5050. APLOS R0-5050 20 páginas. 5 stage reverse osmosis drinking water system, 50gpd
2. Feed Water and Operations Requirements
To achieve the optimal performance, it is highly recommended to use this system
within the following operational parameters.
1
2
Main Pressure (no booster pump), bar
3
Main Pressure (booster pump installed), bar
4
Pressure Tank, bar
5
Inlet Water Temperature, °C
6
Water Supply Connection
Product dimensions, HxWxD
7
(basic assembly) mm
*If feed water pressure is below the requirements, pumped reverse osmosis should
be installed. If the feed water pressure is above the limits pressure valve needs to
be installed on the mains supply.
**It is needed to pump up or release the pressure if it is outside the limits
1
Hydrogen Ion (pH)
2
TDS
3
Hardness
4
Free Chlorine
5
Iron
6
Manganese
7
Chemical oxygen demand
8
Total bacterial count
9
E. coli
NOTE:
Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
If water supply does not meet the requirements, service life of membrane and/or
pre-filter cartridges may be shortened.
4
Water Supply
Feed Water Quality Requirements
Municipal or pre-treated
well water
3 - 6
2 - 4.5
0.4 - 0.6*
+4 - +30**
1/2" Thread
350x450x150
6.5 - 8.5
<1500 ppm
<500 ppm CaCO3
<0.5 ppm
<0.3 ppm
<0.1 ppm
<5 ppm O2
<50 CFU/mL
<3