DURAVIT Utronic 0830370092 Instrucciones de montaje - Página 9

Navegue en línea o descargue pdf Instrucciones de montaje para Productos de fontanería DURAVIT Utronic 0830370092. DURAVIT Utronic 0830370092 16 páginas. Infrared sensor urinal

DURAVIT Utronic 0830370092 Instrucciones de montaje
# 1002110000
Solenoid valve and sensor films.
4
Detach electrical connection and re-
move the electronic unit.
Replacing the solenoid valve
1
Using the screwdriver and close the
stop valve (7 turns).
5
Place the sensor film on the elec-
tronic unit.
2
Using Allen wrench (4 mm) unscrew
the bottom portion of the electronic
unit.
6
Using the Allen wrench (6 mm) un-
screw the solenoid valve.
3
Slide the electronic unit forward.
7
Remove the solenoid valve.
MAL_51173/14.06.8