Filtration System

Apollo Spas are equipped with balanced filtration, meaning that the filter cartridges are sized to meet the needs of
the pump system. As with any water filtration system, the filter cartridge may become clogged, resulting in re-
duced water flow. It is important to maintain a clean, un-obstructed filter system.
Cleaning a Reusable Filter
NOTE: The re-usable FILTER CARTRIDGE should be cleaned with Spray & Rinsed weekly and soaked
whenever the spa is drained. FILTER CARTRIDGES should be replaced at least once every year, or as often
as needed.
1. Turn the power to the spa OFF.
2. Lift up the front face of the filter and slide tray out of the way for total access to the filter.
3. Clean reusable filter as directed above and place back in canister.
4. Slide tray back into place and set the front face of the filter back into position.
5. Turn your spa back on.
Cleaning a Reusable Filter/Replacing a Disposable Filter
NOTE: These models are compatible with either a reusable or disposable filter. If you are using a reusable
filter, please read the note above and then follow the steps listed below.
Disposable filter cartridges are a great option to reusable filters. They typically filter down to a smaller
particle size and never require cleaning. They have a lifespan of 3 or 4 months. The use of Clarifiers and Foam
inhibitors is not recommended with disposable filters! Consult Customer Care for more information on dis-
posable filter cartridges.
1. Turn the power to the spa OFF.
2. Open the AIR VENT BLEEDER, remove the FILTER NICHE COVER (plastic disk-shaped piece)
3. Lift the grey lock tab and remove the lock ring by turning it counter-clockwise.
4. Pull the FILTER LID up and remove it.
5. Rinse the element using a garden hose with a pressure nozzle. Rotate and separate the filter pleats
while spraying in an up/down motion. Let the filter dry, and then inspect the pleats for calcium build
up or an oily sheen. If either are present, consider soaking or replacing the element.
6. Replace the FILTER CARTRIDGE in the opposite order it was removed. The LOCK RING should
easily snap into place. DO NOT turn it past the grey LOCK TAB position (the first click).
7. Turn the power to the spa ON. With the spa operating on the low speed, slowly unscrew the AIR
VENT BLEEDER until the air bleeds out and you have allowed water to bleed out for a few seconds.
8. Then slowly and gently screw the AIR VENT BLEEDER back down until the water stops coming
from the valve.
9. Replace the FILTER NICHE COVER.
10. Run the jets on HIGH speed until you can see, and feel that the water is coming from all the jets.
11. Revert to low speed and set temperature to desired setting.
Filter Replacement
(Discover, Saturn, Commander)
1. Turn the spa off using the on/off button on the topside control panel.
2. Remove the telescoping filter cylinder
3. Unscrew the filter cartridge and either clean the reusable filter or discard the disposable filter.
4. Re-thread the clean or new filter.
5. Replace the telescoping filter cylinder.
(Rainier, Columbia, Chelan, Cascade)
11
(Explorer, Triton, Gemini)