PACKAGE CONTENTS

Tor V alarm transmitter in a plastic encasement
This user manual
Commissioning instructions (47IN0039)
Installation manual – Removal detector (47IN0051)
Tor V (alarm transmitter)
Removal detector
Internal antenna
Ethernet cable (shielded)
SIM card
Sticker to mount on the fire alarm (EN 54-21:2006)
Labels to mark the connections and indicators on the alarm transmitter
Screws and plugs for installation
External antenna for 4G (GPRS/EDGE/4G)
Option: AC/DC adapter 230V/24V
3

CONDITIONS

3.1

Fire alarm installation (EN 54-21:2006)

The service profile of the alarm transmitter is to meet the requirements set forth in
SBF 110:8 (EN 54-21:2006).
The alarm transmitter is to be mounted and connected so that all requirements in SBF
110:8 (EN 54-21:2006) are met.
The pin inputs and relays are connected to meet the requirements set forth in SBF
110:8 (EN 54-21:2006). Use inputs normally closed or with a resistor to detect failure.
The alarm transmitter is to be mounted and voltage supplied from the control panel.
Access to voltage supply from the control panel, with 2A fuses.
Externally mounted antenna with satisfactory signal strength for mobile data
communication.
Marking the outside of the alarm transmitter's encasement with the included sticker.
Follow the instructions in the following sections: 4.1, 6.1, 6.5 and 7
3.2

Alarm installation (EN 50136/SSF 114)

For security class 2, the following apply:
Tor V in a plastic encasement without a battery backup but with a mounted removal
detector.
The service profile of the alarm transmitter is to meet the requirements set forth in
SSF 114:2/EN 50136.
The pin inputs and relays are connected to meet the requirements set forth in SSF
114:2/EN 50136. Use inputs normally closed or with a resistor to detect failure.
The alarm transmitter is to be mounted and connected so that all requirements set
forth in SSF 114:2/EN 50136 are met.
Access to voltage supply of +12V to +30V with battery backup, with 2A fuses for 12V.
Follow the instructions in the following section: 6.2