Caviblaster 0625-G Manual de uso y mantenimiento - Página 5
Navegue en línea o descargue pdf Manual de uso y mantenimiento para Equipos de limpieza Caviblaster 0625-G. Caviblaster 0625-G 15 páginas.
When feeding water to the CaviBlaster
the 1" diameter clear PVC feed hose to the cam-lock plug on the inline strainer
inlet.
The feed hose has the feed pump on one end and a cam-lock socket on the other end. Insert the
electrical plug powering the feed pump into the waterproof electrical outlet on the end of the
power unit cart under the handle. Ensure that the knob on the plug is facing up and mates with
the notch in the outlet cover.
Ensure that the feed hose is connected to the pressure pump, the feed pump is submerged in
water, and the wiring splice is kept dry prior to starting the feed pump.
seawater can be used with this system.
Note: The feed pump has had a neoprene check valve installed in the discharge. This valve will prevent water from
draining out of the feed hose through the feed pump when the pump is turned off. However, this check valve
somewhat restricts the flow of water from the pump. If maximum water flow is required from the feed pump, the
check valve and stainless retaining washer can be removed from the pump discharge by removing the black hose
NEVER TURN OFF FEED PUMP WHILE WORKING.
barb fitting.
When feeding the CaviBlaster
volume of greater than 6 gallons per minute at a maximum pressure of
source to the inlet of the pressure pump (Figure 10).
pressure pump and the water is on prior to starting the pressure pump.
®
power unit with the feed pump, connect
If the plug is engaged upside down, the pump will turn in reverse.
®
with an alternate water source,
the source must supply water at a
70-psi. Connect the water
Ensure that the feed hose is connected to the
Either fresh water or