Datacom Systems Inc
illuminates indicating link has been established between both devices. Connect
DAISY B through DAISY D connectors of the first switch to the COMMON
B through COMMON D connectors, respectively, of the second 4X16SP-
1000BT using DRL366-3 cables and noting link LED illuminates indicating
link has been established between both devices. Repeat DAISY A through
DAISY D connections to the COMMON A through COMMON D connec-
tions, respectively, of any additional 4X16SP-1000BT switches added to the
Daisy-Chain configuration.using DRL366-3 cables and noting link LED illumi-
nates indicating link has been established between connections.
Step 5. Connect either;
a) the MANAGEMENT PORT of the first 4X16SP-1000BT RJ45 connector
to the network for remote console control,
OR
b) the CONTROL port of the first 4X16SP-1000BT USB-style connector to a
local host control console. using the DRL470-6-6-6-6 cable.
Step 6. Connect the LINK port of the first 4X16SP-1000BT USB-style connector to
the CONTROL port of the second 4X16SP-1000BT USB-style connector using
the DRL448-6 cable.Repeat LINK connections to the CONTROL connec-
tions, respectively, of any additional 4X16SP-1000BT switches added to the
Daisy-Chain configuration.using DRL448-6 cables.
Step 7. After the daisy-chain hardware installation is complete, the REMOTEagent
and MANAgents
ured. Please refer to the DATACOMswitch
4X16SP-1000BT Copper Gigabit SPAN Switch • USERguide
switch control software must be configured or reconfig-
SOFTWAREguide for details.
17