DataComm Electronics 45-0032-WH Hoja de instrucciones e instalación

Navegue en línea o descargue pdf Hoja de instrucciones e instalación para TV DataComm Electronics 45-0032-WH. DataComm Electronics 45-0032-WH 3 páginas. Recessed low voltage media plate with 20 amp duplex receptacle

Instruction / Installation Sheet
Recessed Low Voltage Media Plate
with 20 Amp Duplex Receptacle
Part # 45-0032-WH
Parts Included:
• Recessed Low Voltage Media Plate
• Steel Electrical Box
• 20 Amp/125 Volt Tamper Resistant Duplex Receptacle
• Four (4) Electrical Box Mounting Screws
Tools Required:
• Drill with Phillips Bit or Phillips Head Screw Driver
• Pen or Pencil
• Sheetrock Saw or Utility Knife
• 6 Ft. Tape Measure
Use the Recessed Low Voltage Media Plate with 20 Amp Duplex Receptacle to install low voltage cables
behind your HDTV or other display device. The plate can be installed upright or sideways (see Installation
Diagram below).
Features of the Recessed Low Voltage Media Plate with 20 Amp Duplex Receptacle include:
• HDTV/display device plug recesses completely into the wall when plugged into the Media Plate
• 20 Amp Duplex Receptacle and Steel Electrical Box for commercial requirements
• Large low voltage pass through opening for multiple low voltage cables
IMPORTANT INSTRUCTIONS:
This product is designed for retrofit work only
because the electrical outlet box cannot be
attached to a stud.
WARNING:
Before running 12/2 w/ ground UL approved
building wireto the Recessed Low Voltage Media
Plate with 20 Amp Duplex Receptacle, be sure the
power is off by switching the circuit breaker to off
or removing the fuse(s). Test the power to make
sure the power is off. Be sure to install the Media
Plate
with
Duplex
20
Amp
accordance with the National Electrical Code
(NEC) local codes.
WARNING
 DataComm Electronics' products shall be installed and used only as indicated in DataComm Electronics' product instruction sheets.
 Instruction sheets are available online at www.datacommelectronics.com.
CAUTION
 For shock protection, this device must be properly grounded.
 Use copper wire only with this device.
IMPORTANT INSTRUCTIONS
Read and understand all instructions.
Follow all warnings and instructions marked on the product.
Do not use this product near water, for example near a bath tub, wash bowl, kitchen sink, laundry tub, in a wet basement, or near a
swimming pool.
SAVE THESE INSTRUCTIONS.
Receptacle
in
Page 1 of 3
DataComm Electronics, Inc.
6349 Peachtree Street
Norcross, GA 30071-1725
888.223.7977
770.662.8205
www.DataCommElectronics.com
Installation Diagram
11/15/13