CBX500 INSTALLATION MANUAL
DESCRIPTION
The CBX500 is a connection box which can be used as an accessory to facilitate system connections for
installation and device replacement of several Datalogic family reading devices.
System cabling is made through spring clamp terminal blocks inside the CBX500 while the reading device is
connected to the CBX500 through a 25-pin connector on the housing.
A 9-pin connector placed inside the CBX500 facilitates connection between an external PC and the auxiliary serial
interface of the reading device for configuration or data monitoring.
CBX500 can also house several accessories which make the system highly flexible. These include:
Backup Module - to backup and restore system configuration parameters making system maintenance
extremely quick and easy.
Display Module – to show reading device menu and diagnostic messages at the CBX500.
Several Host Interface Modules - to interface the scanner with the most popular Fieldbus
network types: Ethernet, Profibus; DeviceNet, etc., including IP65 protection versions.
Mounting Adapters – to provide easy mounting to DIN rails and Bosch profiles.
ACCESSORIES
The following accessories are available on request for the CBX500:
Name
Description
BM100
Backup Module
BM150
Display Module
BM300/310
Profibus Module STD/IP65
BM400
DeviceNet Module IP65
BM500/510/520
Ethernet/IP Module STD/IP65/IP54
BM600
CANopen Module STD
BM700
Profinet Module STD
BM1100
CC-Link Module STD
BM1200/1210
Modbus TCP STD/IP65
BA100
DIN Rail Adapters
BA200
Bosch Adapters
BA900
Two Cable Glands Panel

SAFETY PRECAUTIONS

ATTENTION: READ THIS INFORMATION BEFORE INSTALLING THE PRODUCT
POWER SUPPLY
This product is intended to be installed by Qualified Personnel only.
This device is intended to be supplied by a UL Listed NEC Class 2 power source.
Total power consumption is given by adding the CBX500 power consumption to that of all the
devices powered through the CBX500 (reading device, P.S., I/O). Refer to the manual of the
connected devices for details about minimum/maximum supply voltage and power
consumption.
CAUTION
Each CBX500 supports only 1 single reading device + system accessories.
4
Part Number
93ACC1808
93ACC1809
93ACC1810, 93ACC1811
93ACC1814
93ACC1812, 93ACC1813, 93ACC1840
93ACC1815
93ACC1816
93ACC1845
93ACC1848, 93ACC1849
93ACC1821
93ACC1822
93ACC1847