DUST FREE
BYPASS HEPA / BYPASS HEPA PLUS INSTALLATION & OPERATION MANUAL
®

UV LAMP INSTALLATION

BYPASS HEPA PLUS ONLY
To maximize the efficiency and life of
the UV-C lamp, clean each lamp before
installation. Use isopropyl alcohol and a
cotton cloth to wipe dust and fingerprints
from the lamp.
Attach lamp to the connector by inserting
the front of the lamp first, then snapping
the back of the lamp into place. See fig.4.
Fig. 4 UV lamp installation.
WARNING
Mercury Hazard. Do Not Break.
UV-C lamp contains a small amount of
Mercury. May cause redness or
irritation. Manage in accordance with
disposal laws. www.lamprecycle.org
WARNING
Electric Shock Hazard.
Can cause injury or death.
Electrical wiring of the unit to the
HVAC system should be done by a
licensed HVAC technician or
electrical installer.
LAMP REPLACEMENT (ANNUALLY)
The lamp should be replaced annually,
even if it appears to be operating normally.
UV-C energy production diminishes over
time.
1. Obtain the correct replacement lamp for
your model.
2. Disconnect power to the equipment.
Allow the lamp to cool 10 minutes before
touching.
3. Remove the four screws securing the
cover. See Fig. 5 on the following page.
4. Remove the old lamp and install a new
lamp, as described in the section above.
5. Reconnect power.
DISPOSAL OF CORE/UV-C LAMP
Dispose of your spent UV-C lamps at your
local recycling center. You may also send
your spent lamps in the same container
you received your replacement lamps to:
Dust Free® Reclamation
1112 Industrial Drive
Royse City, TX 75189
WARNING
UV Light Hazard.
Can cause serious eye and skin
damage.
Do not look at UV-C light. Wear UV-C
eye and skin protection
NOTICE
Qualified Technicians Only.
This device is for residential
applications only and must be
installed in compliance with all
national and local electrical and
mechanical codes. Failure to do so
will void Dust Free® Warranty.