Dust Free Bio-Fighter VersaLight 1SVL16 Manual de instalación y funcionamiento - Página 6
Navegue en línea o descargue pdf Manual de instalación y funcionamiento para Equipos de iluminación Dust Free Bio-Fighter VersaLight 1SVL16. Dust Free Bio-Fighter VersaLight 1SVL16 7 páginas. 1s and 2s ultraviolet light systems
BIO-FIGHTER® VERSALIGHT 1S, 2S INSTALLATION & OPERATION MANUAL
LAMP REPLACEMENT(Annually)
The lamp should be replaced annually even if
it appears to be operating normally. UV-C
energy production diminishes over time.
1. Obtain the correct replacement lamp for
your model.
2. Disconnect power to the equipment.
3. Open the cover of the device. Allow lamp
to cool 10 minutes before touching.
4. Disconnect the electrical connector to the lamp.
5. Remove the remote lamp housing.
6. Unscrew the two knurled nuts of the lamp
retaining bracket and slide the bracket
away from the lamp retaining lip.
7. Carefully remove the UV-C lamp and
replace it with the new lamp. Be sure to
clean the lamp of dust and fingerprints
prior to installation.
8. Slide the retaining bracket back in place
and tighten knurled nuts.
9. Reattach the remote lamp housing. The
remote lamp housing must be in place
prior to attaching the electrical connector.
10. Reconnect electrical connector to the lamp.
11. Reconnect power.
12. Verify operation.
WARNING
Burn Hazard.
During replacement, allow lamps to cool 10 minutes
before removing them. Personal injury may result.
WARNING
Mercury Hazard. Do Not Break.
Each UV-C lamp contains a small amount of Mercury.
May cause redness or irritation. Use proper disposal
techniques in case of breakage.
WARNING
UV-C Light Hazard.
UV-C light can cause temporary or permanent loss of
vision, and sunburn. Take precautions to protect eyes
and skin from direct exposure.
FUSE REPLACEMENT
1. Disconnect power cord.
2. Unscrew the knob marked "Fuse" and
remove fuse.
3. Install new fuse and screw knob back in
place. Only use a 250V/3 amp fuse.
4. Reconnect power cord.
LAMP DISPOSAL
Dispose of your spent UV-C lamps at your
local recycling center. You may also send your
spent lamps in the same container you
received your replacement lamps to:
Dust Free® Lamp Reclamation
1112 Industrial Drive
Royse City, TX 75189
PROPER CLEAN-UP TECHNIQUE IN CASE OF
LAMP BREAKAGE
•
Wear protective gloves, eyewear and mask.
•
Sweep the broken glass and debris into a plastic
bag, seal the bag, and dispose of properly.
Contact your local waste management office for
proper disposal.
• Do not use a vacuum cleaner. Do not
incinerate.
Replacement Parts
UV-C Lamp - 14"
UV-C Lamp - 16"
UV-C Lamp - 20"
UV-C-O3 Lamp - 14"
UV-C-O3 Lamp - 16"
UV-C-O3 Lamp - 20"
Ballast - VersaLight 1S
Ballast - VersaLight 2S
Power Cord (120V)
Power Cord (240V)
Power Cord (Whip-Type) (120V/240V)
Power Cord Receptacle
Slide Bracket Springs (2)
Slide Bracket
Knurled Nuts (2)
Lighted On/Off Switch
Fuseholder
Fuse
For information on the dealer in your area call: 1-972-635-9564.
6
Visit us at http://www.dustfree.com
Part No.
06157
06032
06033
06162
06072
06073
06197
06194
06309
06215
06303
212106-00
210-0005-001
210929-00
210226-00
750-0026-002
212225-00
750-0108-001