Datalogic Gryphon M200 Manual de consulta rápida - Página 9

Navegue en línea o descargue pdf Manual de consulta rápida para Lector de códigos de barras Datalogic Gryphon M200. Datalogic Gryphon M200 18 páginas.
También para Datalogic Gryphon M200: Manual de referencia (20 páginas)

Datalogic Gryphon M200 Manual de consulta rápida
USING
MULTIPLE
CRADLE
If you want to use several readers associated with the same cradle, you must
first Bind the cradle with one of the readers (see previously described
configuration procedure).
Successive readers can be associated with the same cradle by following the
configuration procedure substituting the Bind command with Join.
5.
The green LED on the Gryphon™ M will blink: the reader is ready to be
positioned onto the cradle. Complete step 6.
CAUTION
GRYPHON™ M DEFAULT CONFIGURATION
DATA FORMAT
code identifier disabled (enabled for POS terminals), field adjustment
disabled, code length tx not transmitted, character replacement disabled
POWER SAVE
scan rate 270 scans/s
READING PARAMETERS
operating mode hand-held, hardware trigger, trigger active level, no timeout,
Flash On = 1 sec, Flash Off = 0.6 sec, one read per cycle, safety time 0.5
sec, beeper intensity high, tone 2, beeper type monotone, beeper length
short, good read spot duration medium
DECODING PARAMETERS
ink spread enabled, overflow control enabled, interdigit control enabled,
Puzzle Solver™ disabled, decoding safety = one read
Ì$+RN1$-NÎ
If the cradle is not Bound to a reader, its address assumes
a random value, which can cause conflicts and malfunctions
to other cradles within its range.
READERS
Join
GRYPHON™ MX00
WITH
SAME
5