• Servicing this machine while still connected to a power source could lead to electrocution or fire. Before performing
machine service or maintenance, disconnect the machine from it's power source. Operating this machine with a damaged
power cord could lead to electrocution or fire. Cord should remain clear of moving parts during operation. Never use the
cord to navigate the machine.
Troubleshooting
Problem
Machine will not start
Runs erratically
Fuse/Circuit Breaker Trips
Machine pulls hard to one side
Note: The rubber isolators on the EBG
are considered wear items. It is
recommended to replace the entire
set of all four isolators once per year
(or sooner under heavy use) to prevent
failure and damage to the machine.
Machine is noticeably louder than it
was when originally purchased
6
Cause
•
Not Connected to power source
•
Voltage too low
•
Defective switch
•
Low voltage from excessive length
or
•
undersized extension cord
•
Defective start switch
•
Defective motor low voltage
•
Low voltage
•
Low input volts
•
Worn Pad
•
Rubber isolators are worn out
•
Rubber isolators worn
•
Removable weights
•
not secured
Action
•
Check power source connection and
lighted plug
•
Have electrician check outlet
•
Contact Dustbane dealer
•
Use 10 gauge extension cord
•
Not more than 25' long
•
Contact Dustbane dealer
•
Contact Dustbane dealer
•
Allow the motor to cool. The circuit
breaker is a red button on the side of the
motor that will reset when pressed.
•
Eliminate extension cord.
•
Locate power cord closer to work site.
•
Have voltage checked by electrician.
•
Rotate pad 180 degrees
•
Flip pad over
•
Replace Pad
•
Replace isolators
•
Replace isolators
•
Tighten star knobs on removable
•
weights