2easy DK4761 Manual rápido - Página 4

Navegue en línea o descargue pdf Manual rápido para Sistema de interfono 2easy DK4761. 2easy DK4761 16 páginas. 2 wire intercom system

2easy DK4761 Manual rápido
Star wiring with 4 output distributor DBC4A1
ON
1 2
3 4 5 6
Code=32, DIP-6=on
ON
1 2
3 4 5 6
Code=30, DIP-6=on
ON
1 2
3 4 5 6
Code=4, DIP-6=on
ON
1 2
3 4 5 6
Code=2, DIP-6=on
[1]: Door Station, when there is only one Door
Station, the DIP bit-1 and bit-2 should be set
to 00.
[2]: Power Supply(DR-30-24), MUST be
installed side by side with DPS unit.
[3]: Power Separator, MUST be installed side
by side with the DR-30-24 unit.
[4]: Monitor, each one with a unique User
Code, note that all the bit-6 of the DIP should
be set to 1 (on) in this case.(Max.32 Monitors)
[5]: 4 output distributor DBC4A1,Impedance
switch of all DBC4A1 should be set to OFF,
except the last DBC4A should be set to ON.
(When there is only 1 DBC4A1, should set to
ON).
4
ON
1 2
3 4 5 6
Code=31, DIP-6=on
4
ON
1 2
3 4 5 6
Code=29, DIP-6=on
4
ON
1 2
3 4 5 6
Code=3, DIP-6=on
4
ON
1 2
3 4 5 6
Code=1, DIP-6=on
1
RF CARD
ID=00
A
1 2
3 4 5 6
ON
When Monitor quantity < 20
Twisted cable 2x0.00116 sq.in
Twisted cable 2x0.00155 sq.in
When Monitor quantity > 20
Twisted cable 2x0.00155 sq.in
Twisted cable 2x0.00233 sq.in
Note: The thicker the copper wire is, the longer distances will
be. Best wire to use is 18 Guage twisted, while Cat 5 or 6 are not
recommended.
C
4
4
4
4
Impedance
3
2
+ -
DR-30-24
DPS
Cable Usage
Cable Usage
6
Impedance
OFF ON
switch
5
B
OFF ON
switch
A
B
196ft
196ft
262ft
262ft
A
B
229ft
98ft
229ft
164ft
C
98ft
131ft
C
65ft
98ft
-3-