COMPLIANCE
See the DS8100A Reference Manual for the Declaration of Conformity.
LASER SAFETY
The scanner is classified as a Class 2 laser product according to EN60825-1 regulations and as a Class II laser
product according to CDRH regulations.
Disconnect the power supply when opening the device during maintenance or installation to avoid exposure to
hazardous laser light.
There is a safety device, which allows the laser to be switched on only if the motor is rotating above the threshold
for its correct scanning speed.
The laser beam can be switched off through a software command (see also the Genius™ Help On-Line).
AVOID EXPOSURE
LASER LIGHT IS EMITTED
FROM THIS APERTURE
CAUTION-CLASS 3B
LASER LIGHT
WHEN OPEN
AVOID
EXPOSURE TO BEAM
Warning and Device Class Label
The laser diodes used in this device are classified as Class 3B laser products according to EN 60825-1
regulations and as Class IIIb laser products according to CDRH regulations. Any violation of the optic parts in
particular can cause radiation up to the maximum level of the laser diode (30 mW at 630~680 nm).
1
1
Laser Safety Label
Warning and Device Class Label
2
LASER RADIATION IS EMITTED FROM THIS APERTURE
Laser Safety Label
LASER LIGHT
DO NOT STARE INTO BEAM
CLASS 2 LASER PRODUCT
MAXIMUM OUTPUT RADIATION 1 mW
EMITTED WAVELENGTH 630~680 nm
TO EN 60825-1:2001
Figure A
3
Identification Label
AVOID EXPOSURE
DATALOGIC S.P.A. Via Candini, 2
40012 Calderara di Reno - Bologna - Italy
Manufactured
Model No.
Serial No.
This product conforms to the applicable requirements
of 21CFR1040 at the date of manufacture.