Operating Instructions

Working instructions

Ensure the plastic bags of the filters on BOTH SIDES are removed, and set the plug of the air cleaner into a
standard 220V socket before first use.
Self Check while each new plug in
While each time new plug in to socket and turn it on, it will make a "Beep" sound, the green, yellow and
red lights of the air quality indicator will light up and go out in turn, then the AUTO AND TURBO lights of
the gear position indicator will light up and go out in turn, and the air cleaner will get into standby state.
Turn on the power (standby)
Press (
) key to start up, the blue indicator will light up, the air cleaner will make two "Beep" sounds. For
the first time, start up at middle gear position with medium speed, the yellow lights of the air quality
indicator will light up, and indicate the air quality based on the monitoring results of the air quality sensor
after three minutes (After that, the machine will stay at the previous gear position when starting up).
Shut down
When the air cleaner is in operation situation, you can shut it down by pressing (
a long "Beep" and go into standby state.
Mode & airflow selection
Modes or airflow volume can be changed by rotating the model speed gear knob, you can choose
medium speed - high speed – turbo speed by rotating the knob clockwise, and choose medium speed -
low speed - sleep mode - automatic mode by rotating the knob counterclockwise. The air cleaner will
make a "Beep" sound when changing speed or mode. The corresponding blue indicator will light up to
indicate the gear selected, and the air flow will gently change according to the gear selected.
Timer setting
The timer of the air cleaner can be set for 2H, 4H, 8H, and 12H.
Press (
), the air cleaner will make a "Beep" sound, and the indicator for 2Hrs will light up, the machine
is set to shut down after running for 2 hours. Press (
corresponding indicator will light up to indicate the time frame being selected. If the indicator goes off,
then the timer setting is cancelled.

Air quality indicator

Base on twin sensors figures, it reflect in door air quality into 3 status,
Green: good air quality
Yellow: normal air quality
Red: poor air quality
Please note of the sensors may have deviation while it become dirty.
Please clean the sensors while required.
Sleep mode
When the sleep mode is selected, the air cleaner will operate at the lowest speed, the the air quality
indication light will be switch off, and the brightness of other indicators will be reduced.

Auto mode

When the auto mode is selected, the air cleaner will control the fan motor according to the air quality
detected by the sensor
A. Green: good air quality, the fan motor will run in low speed -> mute mode in cycle for every three minutes
B. Yellow: fair air quality, the fan motor will run in medium speed -> low speed in cycle for every three minutes
C. Red: poor air quality, the fan motor will run in high speed -> medium speed in cycle for every three minutes
) again to choose 4H, 8H, and 12H, the