FOLLOW THESE PROCEDURES
1.
Turn the computer off.
2.
Press EJECT to open cover, then press PLAY to expose heads.
3.
Put tape head cleaner on one side of a cotton swab. Gently wipe the sur·
faces of RECORD/PLAY and erase head (see Fig. 1).
Scrub gently. (If there is any build-up of tape oxide particles on or around
the head gap of the RECORD/PLAY head, it is sufficient reason for unreli-
able performance.)
Also clean pinch roller and other tape bearing surfaces if tape head cleaner
is suitable for this purpose (check label ).
4.
Plug in demagnetizer, and activate it while it is at least one foot away
from cassette heads.
5.
Slowly move demagnetizer up to RECORD/PLAY head and around on
head surface. Rate of motion should be approximately one inch per second
during this time.
6.
Slowly move demagnetizer to erase head and then to all other ferrous metal
surfaces which come into proximity with the tape.
7.
Now slowly move demagnetizer away from heads. Do not deactivate field
until demagnetizer is at least two feet away from heads.
The tape head cleaning and demagnetizing procedure is now complete. Inspect
fH~e0Rr>/P1A
Y, surface for wear. If the tape has worn a groove on head surface
more than a couple of tape thicknesses deep, program reading performance may be
poor. If so, then replacement of tape head is indicated. (Normally few thousand
hours of tape running time have been completed before replacement is required.)