Dataprobe iBoot-DC Manual de inicio rápido
Navegue en línea o descargue pdf Manual de inicio rápido para Interruptor Dataprobe iBoot-DC. Dataprobe iBoot-DC 2 páginas.
What's Included
iBoot-DC Unit
Network Cable
This Quick Start Guide
Connections
1.
Connect Network.
suitable unshielded twisted pair (Cat 5) cabling. When power is connected to the iBoot-DC, the
Link (amber) and Activity (green) LEDs on the network connector indicate when the network
connection is properly established.
2.
Connect Powered Device.
terminals marked OUT. Connect the positive lead to the + and the negative (ground) to the - .
The Positive is switched. The standard connection is to the NO terminal. Screw terminal
assemblies are removable for easier connections.
terminal the power will be ON when the iBoot-DC displays ON.
switch, turn it on, to allow iBoot-DC to control the power.
Make sure that the load does not exceed 12 Amps for 5 - 29.9 VDC or
2 Amps for 30 - 48 VDC.
3. Connect Power
positive lead to the + and the negative (ground) to the - . The iBoot-DC is default power On.
The screw terminal assembly is removable for easier connection.
on when the power is connected to the NC terminal.
Web Browser Access
Factory Default IP Address: 192.168.1.254
Factory Default Security Credentials:
Role
Administrator
User
To access the iBoot from the default IP Address, requires the PC to be on the same local
network (IP Address 192.168.1.nnn). If it is not, change the iBoot IP
Address using one of the methods on the following page.
After pointing the browser to the IP Address of the iBoot, enter the
Administrator Username and Password to access the complete setup
features. Enter the User credentials to access only the power control.
Once the user is validated, the Control and Status is displayed.
To control the power, click on the appropriate button. During power
cycling, the Power Status bar will indicate the temporary status, with a
blue background. Once the cycle is complete, the status bar will
revert to its original condition.
IBoot-DC quick start
iBoot-DC supports 10/100 Ethernet using the cable supplied, or other
Connect the device to be powered ON and OFF to the screw
Connect the DC power source to the terminals marked IN. Connect the
Username
Password
admin
admin
user
user
Quick Start Guide
Available Online at
dataprobe.com/support/iboot
With the positive connected to the NO
If the device has a power
The LED marked Output is
© 2011 Dataprobe Inc.
Complete Product Manual
Device Management Utility
Latest iBoot Firmware
Software Developer Tools
Fig.1 Connect Network
Fig. 2 Connect Device
Fig. 3 Connect Power
Fig. 4 Status and Control Page
V111227E