7
11.4 How to set the slave monitor address
Maximum 4 monitors can be connected in one apartment,one master monitor together
with 3 slave monitors, so you should set the address correctly.(note:must have one
monitor to be set as master monitor)
The code of 8000 is used to set the master monitor.
The code of 8001 is used to set the first slave monitor .
The code of 8002 is used to set the second slave monitor .
The code of 8003 is used to set the third slave monitor .
11.5 How to set the monitor panel on
In default mode,when receive a calling,the master and slave monitors will ring at the same
time,and just the master monitor can display the image while the slave monitors can not.
But the settings can be changed,you can set the master monitor and all the slave monitors
to panel on at the same time when receiving a call, just input the code number of 8006 on
each slave monitor.
11.6 How to set the unlock parameter
Unlock mode:
There are two unlock modes: 1.power-on- to-unlock type:unlock mode=0(by default)
2.power-off-to-unlock type:unlock mode=1.
The code number of 8010 is used to set the unlock mode to 0
The code number of 8011 is used to set the unlock mode to 1
Unlock time:
The unlock time can be changed by yourself at any time.it can be set from 1 to 9 seconds.
The code number from 8021 to 8029 are used to set the unlock time to 1~ 9 seconds.