DO NOT operate with panels or covers removed from the appliance.
FILLING THE WATER HEATER
Open all hot water taps. Open stop cock at the cold water inlet and allow water heater to
fill until water flows through the system. Close each hot water tap after the air is expelled
from its line.
LIGHTING THE WATER HEATER
The water heater must be filled with water before lighting.
Instructions for lighting
procedure are on the inside of the access cover and shown in Figure 4.
The access cover is removed by lifting the cover upwards and away from the water heater.
The unit is fitted with a thermostat that incorporates a Thermal Overload Safety Cut-Out. In
the event of thermostat failure, the Safety Cut-Out will automatically and permanently cut
off the supply of gas to the burner. If this happens, your heater will not light and you should
call your local Dux agent.
FITTING OF PLUMBING INSULATION CAPS
To ensure optimum operating efficiency of the water heater the two Plumbing Insulation
Caps supplied with the water heater must be fitted to the two brass plugs (also provided
with the water heater) used to seal the unused hot and cold water connection fittings on
these dual handed plumbing featured models. Refer Figure 3 below: