CONWIN Duplicator 2 Hoja de instrucciones - Página 3
Navegue en línea o descargue pdf Hoja de instrucciones para Herramienta eléctrica CONWIN Duplicator 2. CONWIN Duplicator 2 4 páginas.
También para CONWIN Duplicator 2: Hoja de instrucciones (4 páginas)

Latex Size Setting Chart | 70 PSI
Balloon
Helium
Size
0.1
5"
Seconds
0.5
9"
Seconds
0.9
11"
Seconds
2.7
16"
Seconds
60/40 Helium/Air Outlet Size Setting Chart
Balloon Size
11"
16"
Foil Balloon Inflation
Place the foil balloon over the inflating outlet. Pinch the neck of the balloon
between thumb and forefinger and press down on the outlet. Support the
foil balloon in an upright position to insure the neck of the balloon does
not fold over the outlet and restrict the flow of helium. When the balloon
has reached the proper pressure the inflator will automatically shut off the
helium flow. Remove the balloon from the outlet and attach a ribbon and a
balloon weight.
Recommendations For Use With An Air Compressor
Most air compressors are factory set to automatically cycle on at 90
PSI and automatically cycle off at 120 PSI. The Duplicator 2 must have a
steady supply of air or gas to produce equal size balloons. For accurate
sizing, it is essential to work within the limits of the cubic foot per minute
capacity of the air compressor.
Air Compressor Required Specifications
• Primary Moisture Filter
• 20 Gallon Storage Tank
• Cycle Pressure: 90 PSI On - 120 PSI Off
• Compressed Air Availability: 6.5 Cubic Foot/Minute @ 90 PSI
Nitrogen
Air
Compressor
0.2
0.3
Seconds
Seconds
1.4
1.4
Seconds
Seconds
2.5
2.6
Seconds
Seconds
7.5
7.6
Seconds
Seconds
Size in Seconds
1.4
4.2
Duplicator 2 Latex Balloon Settings Chart
Settings should be used as guidelines for the Duplicator 2. Please note that size
settings will vary based on user preference, balloon color and manufacturer. To
adjust the size of balloon to your individual preference, it is necessary to inflate test
balloons.
PSI refers to the gauge located on the adjustable regulator connected to the back of
the Duplicator 2. The pressure setting controls the speed of inflation.
SECONDS SETTINGS refers to the tenth of a second increment readouts on the
digital display on the face plate of the Duplicator 2.
Important: To insure consistent balloon sizing when using helium or nitrogen,
check the size of the balloons every 1/3 of a cylinder of gas. If necessary, increase
the size of the balloon by either increasing the time setting or the inlet pressure on
the adjustable regulator.
60/40 Helium/Air Outlet Settings (optional)
Settings should be used as guidelines for the 60/40 Helium/Air
Outlet. The 60/40 Helium/Air Outlet is recommended for use with
11" or larger balloons. For maximum float time on 11" balloons
with a 60/40 mix, use Ultra Hi-Float
®
clip on the Hi-Float
pump. Note: Float times may vary due to
altitude, environmental conditions, and proper balloon sizing.
Shutting Down the Duplicator 2
Close the cylinder valve or shut
off the air compressor.
Important Guidelines When Using an Air Compressor
• Compressor must build up tank pressure before inflating balloons.
• The output setting on the air compressor should not exceed 80 PSI. If
the compressor is set higher than 80 PSI, the Duplicator 2 will out
perform the compressor's storage tank capacity.
• After each job, blow down the compressor to remove water collected
in the tank during compression. The Dual Sizer will require factory
rework and recalibration if moisture enters its system.
• Power surges will affect the accuracy of the Duplicator 2-line voltage
must be steady at 120 volts. Use a power strip with surge protection.
®
with the purple restriction
Release the pressure from the unit by
pressing and holding the Foil Outlet until
all of the gas has escaped. Disconnect
the supply hose and adjustable regulator
from the back of the unit. Remove
regulator from the cylinder.