DVP LB.40WR Manual de instrucciones de funcionamiento y mantenimiento - Página 17
Navegue en línea o descargue pdf Manual de instrucciones de funcionamiento y mantenimiento para Bomba de agua DVP LB.40WR. DVP LB.40WR 20 páginas. Vacuum pumps with recirculating lubrication system
EN
6.3
SPARE PARTS
Use Original Spare Parts to replace pump parts.
When purchasing spare parts, always quote the serial number and model of the pump (these can be found on the
identification plate) as well as the spare part purchase number.
DESCRIPTION
Air exhaust filter kit
Maintenance kit
Oil 1 dm³
Oil 2 dm³
Oil 5 dm³
Oil sight glass
Oil viewer
Intake filter cartridge
D.V.P. Vacuum Technology S.r.l. disclaims all responsibility for any deterioration of pump performance or for
damages caused due to use of non-original spare parts.
7
HOW TO RETURN THE PUMP
The product may only be returned after prior agreement with the supplier, who will provide the authorisation number
that must accompany the material delivered and should be duly complete in its entirety.
8
DISMANTLING
Demolition of the pump must be performed by authorised technicians.
Metal parts can be disposed of as scrap metal.
All materials deriving from demolition must be disposed of according to regulations in the country where the pump
will be demolished.
HAZARD
Disposal operations involve risks of cutting, shavings protection, entanglement, contact with
moving parts and contact with chemicals. Operators should use the appropriate personal
protective equipment.
8702037 – 01/01/2011 – R.0
Operating and Maintenance Instructions
LB.5WR – LC.25WR – LB.40WR – LB.60WR – LC.105WR
LB.5WR
LC.25WR
K9690029
K9690029/1
K9690035/1
- - - -
- - - -
1801019
LB.40WR
K9690035
K9690031
K9690031/1
8832100 (SW60)
8812100 (BV68)
8832200 (SW60)
8812200 (BV68)
8832500 (SW60)
8812500 (BV68)
5503002
LB.60WR
K9690032
K9690032/1
8833500 (SW100)
8813500 (BV100)
1105004
- - - -
www.dvp.it
LC.105WR
K9690034
K9690034/1
- - - -
- - - -
15