ADE PWI30 Manual de instrucciones - Página 5
Navegue en línea o descargue pdf Manual de instrucciones para Scales ADE PWI30. ADE PWI30 16 páginas. Electronic bench scales portion scale with induction charging
Your ADE portion scale with induction charging is a quality product.
It is ideal for use wherever dusty or harsh working conditions prevail, including professional
commercial kitchens, bakeries, butcher shops, etc. With the ProSeal technology, the
annoyance about dirt, dust, splashing water and corrosion is a thing of the past.
Thanks to the induction charging used, the scale has no interfaces at all in order to avoid
corrosion or contamination of connections. From the polymer membrane to the foot thread, it
offers a completely sealed housing with IP65 dust and splashing water protection that has
been intelligently designed and moulded to meet the highest demands, with no inaccessible
grooves, gaps or acute angles at all. In addition, the weighing surface and the supporting
substation can be disassembled in no time thanks to a practical quick-release fastener. Ideal
for all-round easy cleaning that leaves no residues behind.
Backlight and automatic power-off, as well as the display of different units can be set or
disabled.
To achieve precise results, please read the user guide carefully and follow the instructions
contained therein.
Inspecting the contents of the box
➢ Portion scale
➢ Load cross, silicone mat and weighing plate
➢ Quick-release fastener for the load cross
➢ Induction charger
➢ User manual incl. declaration of conformity
Safety information
The induction charger generates an electromagnetic field. This can pose
a threat to persons with pacemakers or other implants!
Never attempt to charge the scale with/on an induction hob/cooker. This
is NOT technically feasible and can also cause destruction of the scale.
Mains and battery connection of the scale
Power is supplied either by means of the rechargeable batteries already installed in the device
or through mains operation using the included AC adapter (230 V AC). The printed voltage
level must comply with the local voltage.
-
The rechargeable batteries are already installed in the scale housing.
-
When charging the device for the first time, use the included AC adapter. The charging
time is approx. 12 hours during initial charging.
-
When fully charged, the scale has an operating time of up to 120 hours.
PWI30-190920-Rev005-UM-en
Scale installation and operation
4