Dateq DNA-Dymand Manual
Operation
9
EN
st
LOCUT: The locut-switch activates a 80 Hz, 1
order, highpass-filter before the detectioncircuit. In
this way the Dymand will be less conscious of low frequency contents of the signal. The principle of
the low-cut filter is that the Dymand, like your ears, will be less conscious of low frequencies.
STEREO-LINK
The Dymand is a dual channel compressor. It can of course be used as a stereo compressor, by
using the stereolink-function. The stereolink function of most compressors only links the compression
process. When using this kind of stereo link, the channnel that requires most gain-reduction controls
the other.
In stereo link, the Dymand links both compression- and expansion-process and all rotary-controls
(outputlevel optional, see drawing). The compression-process is linked with high-priority (highest
gain-reduction), while the expansion-process is linked with low-priority (lowest gain-reduction). In
effect this means that both the compressor and expander follow the highest signal and not the
highest gain-reduction.
Linking of the rotary-controls, expander-threshold, threshold, ratio, attack and release saves
adjustment-time, both channels will be set exactly the same in stereo link. Linking of the output-level
control is optional via an internal jumpersetting, which can be found on the large upperboard on the
frontside of the Dymand.