1
CHANNEL INPUTS
Each channel has two inputs:
XLR input - This is a balanced input.
It accepts mic or line level signals
depending on the adjacent gain switch
position. The XLR will also have +15V
phantom power if selected on the
adjacent switch.
RCA input - This is an unbalanced line
level input. The two RCA sockets are
summed to mono internally.
2
P/P – PHANTOM POWER
15V phantom power is available for
condenser or electret microphones on
the XLR input when this switch is in
the "ON" position.
3
MIC / LINE
These two switches control the sensitivity
of the XLR input. In the "MIC" position
the XLR input is suitable for use with
microphones; in the "LINE" position the
XLR input is suitable for use with a
balanced line level signal.
NOTE: Both MIC/LINE switches
must be in the same position
for correct operation of the
balanced input.
NOTE: The MIC/LINE switches
only affect the XLR input.
MX61 INSTALLATION & OPERATION MANUAL
5
4
4
REC OUT
The REC OUT output is on unbalanced
RCA connectors. The output is dual mono
and is not affected by the MASTER volume
control or the EQ tone controls.
5
OUTPUT
The OUTPUT XLR provides balanced line
level signal.
6
24VDC SOCKET
This 2.1mm x 5.5mm barrel socket is
provided for 24V emergency systems and
is not switched by the front panel power
switch.
3
NOTE: When wiring the LINE
output as unbalanced, Pin2
should be wired as hot and
Pin1 should be wired as
ground/shield. Do not wire Pin3.
NOTE: The 24VDC socket does not
provide trickle charge facility. Tip
of the connector is positive.

REAR PANEL

2
1
7
IEC MAINS INPUT SOCKET
This is a standard IEC 3 pin socket.
It accepts a standard IEC mains cable,
provided. The fuse draw contains the
mains fuse and a spare. The mains fuse
is a time lag (slow blow) HRC 20mm x 5mm
ceramic type fuse.
The ratings are:
230V/240V model 63mA
115V model 120mA
Always replace the fuse with one
of the same value and type.
NOTE: Always disconnect
power to the amplifier before
replacing fuses.
8
OPTIONAL MODULE INPUTS
This socket is used with a tone module
and/or VCA module.
PAGE 5