AUSTRALIAN POOL EQUIPMENT PRISTINE PRI-35 Manual del usuario - Página 9
Navegue en línea o descargue pdf Manual del usuario para Aspirador de piscinas AUSTRALIAN POOL EQUIPMENT PRISTINE PRI-35. AUSTRALIAN POOL EQUIPMENT PRISTINE PRI-35 12 páginas. Auto self cleaning
HOW DOES THE SELF CLEANING Pristine CELL WORK?
To describe the operation simply, the Pristine Chlorinator controls the forward direction of
the cell for a period of 12 hours.
It then stops for a short period before slowly ramping up to the set power level in the
reverse direction for a period of 12 hours. This reversing process is repeated continually
and assists greatly in reducing calcium build-up in the cell.
When the Pristine Chlorinator is reversing the direction of the cell, all "Menu Operations"
become inactive during the changeover period.
The Pristine Chlorinator also monitors the power passed through the cell when in forward
or reverse direction. The "Dynamic Cell Balancing" technology constantly tracks the
power output to further assist in eliminating scale build up and uneven cell wear.
Therefore, the cell is almost maintenance free.
Heavy bathing leads and excess suntan lotion can coat the cell and affect chlorine
production over an extended period and the cell may need a light acid wash every six
months.
CLEANING MIXTURE: 1 part pool acid to 10 parts water
NOTE: Excess acid will damage the cell.
HOW DO I MAINTAIN THE CELL?
If at any time you find it necessary to clean the cell please follow the following steps:
1.
Create a "cleaning mixture" in a container consisting of 1 part pool acid to 10 parts
water. DO NOT USE MORE ACID.
2.
Switch off the chlorinator power and unplug from power outlet.
3.
Remove the cell from the housing by unscrewing the cell cap.
4.
Place cell into container of cleaning mixture and leave for a few minutes to
dissolve scale build up. DO NOT SCRATCH OR SCRUB - This will damage the
coating and void the warranty.
5.
If the scale build up does not dissolve after approximately 10 minutes, create a
new mixture and repeat the process.
6.
Replace cell in housing and screw cap back on, ensuring that it has been fitted
securely.
7.
Plug in Pristine Chlorinator and switch power on.
Page 15
MAIN OPERATING SCREEN
Mode:Timer
MODE
Chlorine Output:
Displays the current MODE of
operation from the list of modes
on the following page.
Status: OK
Chlorine Output
Displays the current level of chlorine production as both a percentage and as a bar graph
to an accuracy of 1%.
To increase chlorine output press the [▲] button.
To decrease chlorine output press the [▼] button.
STATUS
Display the system status.
OK
Current condition is normal
LOW SALT
Indicates when a low salt condition is present
SALT HIGH
Indicates when a high salt condition is present
PRIMING CELL
Chlorinator is waiting for pump to start and deliver water to
the cell.
PUMP FAIL
Cell did not become primed in the allotted time (only occurs if
PUMP PROTECTION is enabled).
CHANGING MODES
There are two ways to change the MODE. You can cycle through OFF, ON, and TIMER
modes via the MAIN OPERATION SCREEN by pressing the [ENTER] button. Each time
the [ENTER] button is pressed the MODE is advanced to the next and then repeats.
Alternatively, you can change the MODE via the MAIN MENU, and in so doing, will be
able to invoke the SUPERCHLORINATE and SPA modes which are not accessible from
the main operating screen.
To enter the MAIN MENU press the [MENU] button.
Use the [▲] and [▼] buttons to navigate the MAIN MENU until the arrow indicates that
you have reached MODE SELECT. Now press the [ENTER] button.
Page 8