CENTRAL HEATING CONNECTION (ONLY EKR)
The heat exchanger is suitable for connection to a water heater at a pressure of up to 6 bar. A forced
circulation with pump is required. If the storage tank is connected to alternating current, the pump can
be controlled via the free charge pump contact. The temperature setting of this contact is identical to the
temperature level of the two contacts for the fitted electric heater.
The bare-tube heat exchanger of the EKR series must be flushed properly before the initial installation is
performed. If the bare-tube heat exchanger is not used, the outer tube ends must be sealed to prevent
back-cooling.
In the event of a combination with boilers or gas fired water heaters, an additional sensor protection tube
(clear width 9.5mm) is fitted in the heating flange for insertion of the sensor (to be provided on site – capil-
lary tube or electronic sensor). The sensor tube protrudes above the topmost coil of the heat exchanger.
If a hot water storage tank with bare-tube heat exchanger is installed, a shut-off element or circulation
brake should be fitted in the inflow line to prevent backheating into the heating circuit when the central
heating is switched off and electric operation is active.
However, under no circumstances is it permissible to shut off the inflow line and the return line because
this would make it impossible for the water inside the heat exchanger to expand, which could damage the
heat exchanger.
If the water heater is heated by its heat exchanger, then it must be ensured that in no case the hot water
temperature exceeds 85 °C, as otherwise the safety temperature limiter of the electric heater can trigger
and render it inoperable.
In order to allow for a trouble-free repair, a removal or exchange of the device, it is necessary to establish
the connection of the tank by means of a detachable connection (Dutch). Tank leaks as a result of an im-
proper connection and resulting damage and consequential damage are excluded from the warranty and
product liability.
ELECTRICAL CONNECTION
General information
a) As a general rule, the electrical connection must be made in accordance with the wiring diagram glued
inside the connection chamber of the storage tank!
b) Ensure that the supply voltage is correct!
c) Fit an all-pole disconnector with 3mm contact opening width in the electric feeder. Automatic circuit
breakers can also be used as disconnectors.
d) The connection cable must be fed through the cable screw connection into the connection chamber of
the storage tank and protected with a strain relief mechanism against pulling out and twisting. Tanks
with heater battery have a second cable entry point for the charge pump control cable.
e) For installation and intrusive interventions into the device, the hot water storage tank must first be isola-
ted completely (all poles) and on every side from the power supply in compliance with EN 50110 (ÖVE,
TAEV). Before carrying out any additional work, the system must be secured against being switched on
again (remove the fuses, trigger the mains circuit breaker).