The soup well system uses SmarTemp™ technology to actively control the
temperature of the pan. Factory setting allows the user to choose from four
temperature settings in Fahrenheit or Celsius. The number of temperature settings
can also be increased to fifteen total using the "Changing the Temperature Settings"
option on page 5, and the temperature scale changed between Fahrenheit and
Celsius using the "Changing the Temperature Scale" option on page 5. The unit is
also equipped with a rethermalization mode to quickly warm cold or frozen soup.
User Interface Buttons
Power Button – Use this button to turn the unit on and off. A green LED
will indicate when the unit is on.
Lock Button – Use this button to prevent users from adjusting settings.
Pressing this button three times will lock the unit. When the unit is locked,
the only button that will continue to work is the Power button. To unlock
the unit, press the Lock button three times. The red LED to the right of
the button will indicate when the unit is locked. Pressing the lock button
once will also display the current timer value (when the timer feature
is enabled).
Up and Down Arrows – These buttons allow you to quickly set
the temperature or choose rethermalization mode.
Alphanumeric Display – Displays holding temperature
(Fahrenheit or Celsius) and error code information.
Control Panel
The soup well is designed to be used with an 11qt (10.4 L) bain marie soup tureen.
The unit should not be operated without using the water bath. An adapter ring
can be purchased separately to allow the unit to work with a 7 qt (6.6 L)soup tureen.
CookTek's soup well is in conformance with ANSI/UL 197 and CSA 22.2 No. 109
standards and bears the commercially rated approvals. CookTek's soup well is in
conformance with European Economic Area standards and bears the CE marking
signifying European Conformity.
GENERAL INFORMATION
Heating
At Temp
POWER
APPROVED FOR COMMERCIAL USE
LOCK
3