2easy 2-wire Series Manual - Página 12

Navegue en línea o descargue pdf Manual para Accesorios 2easy 2-wire Series. 2easy 2-wire Series 17 páginas. Door station flush mount

2easy 2-wire Series Manual
Unlocking Time Setting via Door Station
The unlocking time can be set to 1~30 seconds. The default is 1s
1)Power-on and within 5 sec
2)Press and hold "B" button for 3
seconds to enter programming
mode
background indicator
(flash)
Note: Unlocking time can be program via monitor as well
Buzzer
beep+,beep
-11-
Press and hold "A" button for 3
seconds
background indicator
(off)
At this time press and hold "B"
button,timing starts; release "B"
button to end the timing. The
time of press and hold "B" button
equal to unlock time.(Timing Unit:
1s)
background indicator
(flash once per second)
Buzzer
beep+,
Buzzer
beep once
per second