7. Special advice

Please mind that all surfaces of the insert heat up extremely during operation. Please
use the heat-proof glove, which comes with the insert. Please also make your children
aware of this danger and keep them away from the fireplace during operation.
In order to avoid a heat build-up, please DO NOT cover or close any air grids/in-
/outlets.
Every insert is made for a special fuel load and therefore has its own maximum fuel
quantity. Bigger quantities than the ones listed below may lead to overheating and
damages of the fireplace!
Maximum fuel quantities – pls. see 3. technical data
The second fuel reload should be made after approx. 45 min after the first. Further fuel
reloads can be made, but please prolong the intervals and reduce the fuel quantity (by 0,5 –
1 kg).
If the manufacturer's dimensional instructions for combustion air cross sections and flue
dimensions cannot be kept or are changed afterwards, all warranty and guarantee claims
end.
No flammable elements may be placed in the insert's radiation area closer than – see 3.
technical data measured from the bottom edge of the combustion chamber. Next to the
fireplace casing a maximum distance of 5 cm must be kept for objects made of flammable
materials.
measure „a") see techn.data „radiation area around glass"
construction type A1: Inserts are tested and certified according to this type and are
equipped with a self-closing door, which means that an operation with open door is
no longer allowed. This means that special closing mechanisms have been installed
on the insert, to avoid the door staying open during operation. It is not allowed to carry
out modifications on the insert, which may afterwards allow the operation of the insert
with an open door. For putting in more wood or cleaning the door glass, the door must
be held open against the clamping force of the door spring or the sliding mechanism
and it must not be blocked with any jamming gadget.
Only original spare parts or spare parts which have explicitly been approved or offered
by the manufacturer may be used. Please ask your stove fitter or a specialised
Austroflamm dealer.
The insert/fireplace must not be modified!

8. Air supply in the installation room

The fireplace can only operate correctly if there is a sufficient air supply in the installation room
respectively for the insert. Take care of a sufficient air supply before you start firing up your fireplace.
Open the combustion air flap on the fireplace and keep it open during the whole time of operation.
Equipment concerning the combustion air supply must not be altered.