Technical data
4. Technical data
4.1 Tabular data
Insulation coordination acc. to IEC 60664-1/IEC 60664-3
Rated voltage ........................................................................................................................................................ 12.5 V
Overvoltage category.....................................................................................................................................................III
Pollution degree............................................................................................................................................................. 2
Rated impulse withstand voltage .......................................................................................................................... 800 V
Rated insulation voltage ...................................................................................................................................... 12.5 V
Altitude ..................................................................................................................................≤ 2000 m above sea level
Nominal voltage/nominal current
Nominal voltage DC 3.3/5 V
Nominal voltage tolerance ....................................................................................................................................± 5 %
Nominal current < 100 mA
Environment/EMC
EMC ........................................................................................................................................................... EN 61851-22
Operating temperature.............................................................................................................................-25...+75 °C
Classification of climatic conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) 3K5 (except condensation and formation of ice)
Transport (IEC 60721-3-2) ....................................................................................................................................... 2K3
Long-term storage (IEC 60721-3-1)......................................................................................................................... 1K4
Classification of mechanical conditions acc. to IEC 60721:
Stationary use (IEC 60721-3-3) .............................................................................................................................. 3M4
Transport (IEC 60721-3-2) ..................................................................................................................................... 2M2
Long-term storage (IEC 60721-3-1)........................................................................................................................ 1M3
Connection
Connection to charge controller................................................................................................................via RJ45 cable
Connection to RFID module ......................................................................................................................via RJ45 cable
Cable length.......................................................................................................................................................... < 1 m
DPM2x16FP_D00296_01_M_XXEN/09.2017