BENDIX AD-IS PuraGuard Datos del servicio - Página 13

Navegue en línea o descargue pdf Datos del servicio para Deshumidificador BENDIX AD-IS PuraGuard. BENDIX AD-IS PuraGuard 15 páginas.

BENDIX AD-IS PuraGuard Datos del servicio
BENDIX
SYMPTOM
5. Cannot build system air
pressure.
6. Air dryer does not purge or
exhaust air.
7. Desiccant material being
expelled from air dryer purge
valve exhaust (may look like
whitish liquid or paste or
small beads.)
8. Unsatisfactory desiccant life. A. Excessive system leakage.
9. "Pinging" noise excessive
during compressor loaded
cycle.
10. The air dryer purge piston
c y c l e s r a p i d l y i n t h e
compressor unloaded (non-
compressing) mode.
®
AD-IS
®
AIR DRYER AND RESERVOIR SYSTEM
TROUBLESHOOTING CHART
CAUSE
A. Supply pressure to the air dryer is not
suffi cient.
B. Kinked or blocked (plugged) discharge
line.
C. Excessive bends in discharge line
(water collects and freezes).
D. Pressure protection valve(s) in air
dryer will not open.
E. Refer to Symptom 4.
F. Refer to Symptom 7.
A. Faulty air dryer purge valve.
B. See Causes B, E, and F for Symptom
#4.
A. Faulty dryer cartridge.
B. Excessive dryer vibration.
B. Wrong vehicle application for AD-IS
air dryer.
C. Compressor passing excessive oil.
A. Single cylinder compressor with high
pulse cycles.
A. Compressor fails to "unload".
REMEDY
A. Ensure the supply pressure to the air dryer is greater than
110 psi after the system charges.
B. Check to determine if air passes through discharge line.
Check for kinks, bends, excessive carbon deposits, or ice
blockage.
C. Discharge line should be constantly sloping from compressor
to air dryer with as few bends as possible.
D. Replace air dryer (pressure protection valves are not
serviceable).
E. Refer to Symptom 4, Remedy A.
F. Refer to Symptom 7, Remedies A and B.
A. After determining air reaches purge valve control port by
installing a T-fi tting with a pressure gauge into the governor
unloader port, repair purge valve if necessary.
B. Refer to Symptom 4, Remedies B, E, and F.
Also refer to Symptom 1, Remedy B.
A. Replace the Bendix
AD-IS
®
dryer.
B. Check the AD-IS air dryer mounting for looseness or damage.
Repair mounting and replace cartridge.
A. Refer to Symptom 1, Remedy A.
B. Refer to Symptom 2, Remedy C.
®
C. Check for proper compressor installation; if symptoms
persist, replace compressor. Refer to Bendix Advanced
Troubleshooting Guide for Air Brake Compressor (BW1971).
A. A slight "pinging" sound may be heard during system build
up when a single cylinder compressor is used. If this sound
is deemed objectionable, it can be reduced substantially by
increasing the discharge line volume.
This can be accomplished by adding a 90 cubic inch (or
larger) reservoir between the compressor and the AD-IS air
dryer and reservoir system.
A. Check air hose from governor to compressor for a missing,
kinked or restricted line. Install or repair air hose.
Repair or replace compressor unloader.
air dryer cartridge or AD-IS air
®
13