Bendix/King Skymap IIIC Manual del piloto - Página 11
Navegue en línea o descargue pdf Manual del piloto para Transceptor Bendix/King Skymap IIIC. Bendix/King Skymap IIIC 14 páginas. Global positioning system
También para Bendix/King Skymap IIIC: Manual (6 páginas), Referencia rápida (6 páginas)
Remote Channel Request
This switch, when momentarily pressed, will perform one of two functions. If the
KFS 599A is in the manual frequency mode, it will change to the preset channel
mode. If the KFS 599A is already in the preset channel mode, it will change the
channel to the next higher programmed channel.
Program Disable
This line will disable and enable the programming function of the KFS 599A. The
Program Disable line is read only during the power-on sequence; any changes
made after power-on are not read.
ADF Enable
This line will enable and disable the ADF mode of the KFS 599A. The ADF
Enable line is read only during the power-on sequence; any changes made after
power-on are not read.
Semi-Duplex Inhibit
This line will disable and enable the use of the semi-duplex feature of the KFS
599A. Any channels programmed as semi-duplex will transmit on the receive fre-
quencies while semi-duplex is disabled. The Semi-Duplex Inhibit line is read only
during the power-on sequence; any changes made after power-on are not read.
Remote Guard Select
While in the Main mode, pressing this switch will select the guard channel.
Pressing this switch while in the Guard mode will select the last active Main fre-
quency.
Faults and Tests
Transmission Time-out Fault
If the transmitter is active for more than 90 seconds, a transmit time-out fault
occurs. This is indicated by the flashing of every illuminated segment of the dis-
play. The transmitter will go inactive until the fault is found or an interruption
occurs in the DC power supply. In most cases, the transmission time-out is
caused by the microphone PTT button being stuck or if a transmission exceeds 90
seconds (including 1kHz Tone Test).
1kHz Tone Test
Pressing the PUSH TONE button modulates the signal with a 1kHz tone. This ver-
ifies the operation of the transmitter and the audio system. This feature is disabled
while the unit is in the BOTH receive mode.
9