Gage Bilt GB108 Manual de instrucciones original - Página 10
Navegue en línea o descargue pdf Manual de instrucciones original para Herramientas Gage Bilt GB108. Gage Bilt GB108 16 páginas. 20v battery installation tool
Additional Actuator Assembly (VP1316) functions:
Note: The installation tool has two additional functions that are controlled with the actuator assembly (VP1316).
1.
Service position: Press the actuator assembly (VP1316) for five seconds (until the white LED on the tool starts to flash (1 /sec) and
release again. The installation tool remains in the rearmost position. The anvil insert can now be easily changed or the clamping
jaws serviced. Press the actuator assembly (VP1316) briefly and the tool moves to its starting position again.
2.
Auto and Manual mode:
a. In Manual mode, hold the actuator assembly (VP1316) depressing during setting of the fastener until the mandrel is sheared off.
b. In Auto mode, you only have to press the actuator assembly (VP1316) briefly and the installation tool controls the fastening
process automatically.
3.
To change from one mode to the other, hold the actuator assembly (VP1316) pressed for ten seconds (until the white LED on the tool starts
to flash (2 sec.) and release again. Press the actuator assembly (VP1316) briefly and the tool moves to its starting position again.
Attaching the Belt Clip (VP1322):
Note: Always ensure belt clip (VP1322) is secure to the installation tool before using.
1.
Attach the belt clip (VP1322) to the foot of the installation tool using the screw. A corresponding thread and slots are recessed in the foot
of the housing on both sides of the installation tool.
2.
Check at regular intervals that the belt clip (VP1322) is still securely attached. Otherwise, retighten the screw.
SLOTS FOR BELT CLIP (VP1322) (2X)
BELT CLIP (VP1322)
Battery (VP1086) Storage:
1.
Protect the battery (VP1086) from moisture and liquids. Do not leave in car e.g. in the summer.
2.
Store the battery (VP1086) only in optimum temperature range between -22°F (-30°C) and 77°F (25°C). The batteries can be stored as
follows without recharging:
Storage period between 22°F (-30°C) and 77°F (25°C) = 1.5 years
Storage period between 22°F (-30°C) and 113°F (45°C) = 3 months
Storage period between 22°F (-30°C) and 140°F (60°C) = 1 month
3.
A significantly shorter operating time after recharging indicates that the battery (VP1086) is worn out and needs to be replaced.
Observe all local disposal procedures.
GB108 20V BATTERY INSTALLATION TOOL S/N: 1143 AND ABOVE
PLEASE CONTACT GAGE BILT FOR ALL OTHER SERIAL NUMBERS.
HOW TO SET-UP THE GB108 Cont.
SCREW
10
Image may not
reflect actual tool
7/21 REV 12/22