WARNING:
Tool must be maintained in a safe working condition at all times and examined on a daily basis for damage or
wear. Any repair must be done by qualified personnel trained on Gage Bilt procedures.
WARNING:
Excessive contact with hydraulic oil and lubricants must be avoided.
WARNING:
Maintenance personnel
WARNING:
Disconnect tool from its power source before performing maintenance, cleaning or when replacing worn or
damaged components. Severe personal injury may occur if power source is not disconnected.
WARNING:
Read safety datasheet documents for all applicable materials.
Note:
•
Dispose of hydraulic oil in accordance with manufacture safety datasheet.
•
All tool materials are recyclable except rubber o'rings, seals and wipers.
The performance of any tool depends upon good maintenance practices. Following these minimal requirements daily will extend the
life of your tool.
* Only use a clean dry air supply set at 90 - 100 p.s.i. (6.2 - 6.9 bar) Max. equipped with a filter-regulator to prevent wear.
* Check tool and nose assembly for damage. (Replace/Repair if necessary). See Overhaul pg. 13 for tool repair.
* Inspect all hoses and couplings for wear, damage and leaks. Replace/Repair if necessary. (See hydraulic thread preparation below).
* Verify that hydraulic hose fittings and couplings, air and electrical connections are secure. Tighten, Replace or Repair if necessary
(See hydraulic thread preparation below).
* Cycle the tool several times to assure there are no leaks during use.
* Keep hydraulic system free of dirt. Avoid letting couplers contact a dirty floor.
* Proper care by operators is necessary in maintaining full productivity and reducing downtime.
* Keep nose assemblies, especially jaws, clean and free of chips and debris. Lube jaws and collet surfaces that jaws ride on with
light machine oil on a daily basis.
* All Screwed End Caps, Base Covers, Air Fittings, Air Actuators, Screws and Nose Assemblies are to be examined at the end of
each working shift to check that they are secure.
•
Check oil level in reservoir on powerunit. See powerunit manual.
SEE TROUBLESHOOTING (PG. 12) AND OVERHAUL (PG. 13) FOR FURTHER GUIDANCE.
IMPORTANT:
Be sure to use thread sealant on all hydraulic fittings, Loctite® 545 or equivalent or a non-hardening Teflon® thread
compound such as Slic-tite®. Tighten until fitting feels snug and then continue to tighten 1/2 to 1 full turn.
can easily distort the threads. DO NOT USE TEFLON® TAPE.
properly applied, pieces of Teflon® may enter the hydraulic system and cause a malfunction or damage.
1.
Remove vacuum regulator (703515) from tube and fitting.
2.
Remove (4) S.H.C.S. from front of regulator and disassemble.
3.
Clean both pieces in clean mineral spirits and blow dry.
4.
Reassemble and connect hoses.
5.
Check vacuum pressure using vacuum gage (703567) (sold separately).
Press gage against the vacuum line or nose assembly to create seal.
Optimum vacuum pressure at nose assembly must be
between 15 - 22 inHg. (381 - 558.8 mmHg).
Note: The vacuum regulator may visually appear clean, but still may be
contaminated with a thin film, therefore, the steps above must
be performed to assure best performance.
Socket Head Cap Screws (400064 & 400066) = 40 inch lbs. (4.52 Nm).
End Cap (743214) = 45 foot lbs. (61 Nm).
Button Head Cap Screws (402482) = 35 - 40 inch lbs. (3.95 - 4.52 Nm). (Do NOT over-tighten).
GB743SHAVT/6NF
DAILY MAINTENANCE
MUST
read and understand all warnings and cautions.
WEEKLY MAINTENANCE
HYDRAULIC THREAD PREPARATION
CAUTION:
HOW TO CLEAN VACUUM REGULATOR
TORQUE SPECIFICATIONS
Teflon® tape is an excellent thread sealer, however, if it is not
703515 Vacuum Regulator
(
4) S.H.C.S.
Fitting
10
CAUTION:
Over tightening
Tube
Image may not reflect
actual tool
10/22 REV 3/23