Dyna-Glo RA18LPDGP Manual del usuario - Página 14
Navegue en línea o descargue pdf Manual del usuario para Calentador Dyna-Glo RA18LPDGP. Dyna-Glo RA18LPDGP 16 páginas. Propane construction heater
También para Dyna-Glo RA18LPDGP: Manual del usuario (19 páginas)
PROPANE CONSTRUCTION HEATER
TROUBLESHOOTING (continued)
Problem
Gas odor even when control knob is
in OFF position.
Gas odor during combustion.
Heater shuts off on ODS.
Possible Cause
1. Gas leaks. Refer to front of page
Warnings.
2. Gas control defective.
1. Foreign matter in gas or on burner ports.
2. Heater burning vapors form paint,
impurities in air.
3. Gas leaks, refer to front page Warnings
1. Not enough fresh air is available.
2. Low gas pressure.
3. ODS pilot partially clogged.
1-877-475-5660
What To Do
1. Locate and correct leaks immediately.
2. Replace gas control
1. Check gas passage way and burner.
2. Ventilate room, stop storing and using
odor causing products near heater.
3. Locate and correct leaks immediately.
1. Open window.
2. Contact gas supplier.
3. Clean the pilot.
1-877-475-5660
14