Great Circle GUT052 Manual del usuario - Página 4

Navegue en línea o descargue pdf Manual del usuario para Equipos de control de insectos Great Circle GUT052. Great Circle GUT052 5 páginas. 3gal./12l fogger

7. Problem and Solution

Problem
Fan not running.
Machine run, no spray.
Intermittent spray, small
spray.
Machine abnormal
sounds.
Poor atomization,
spray nozzle dripping.
Sprayer temperature
too high.
3
Reason
Power plug loosed.
Poor contacted or power wire copper
core broken.
2. Power switch fault.
3. Motor fault.
4. Motor carbon brush rust or run out.
1. Chemical tube or valve blocked.
2. Chemical tube or tank inflatable
tube folded.
3. Chemical tube fell off.
4. The air inlet blocked.
1. Chemical tube blocked,
2. Chemical tube folded.
3. Chemical tube damaged.
4. Chemical tube fell off.
1. The air inlet blocked.
2. Motor bearing damaged or carbon
Brush run out.
1 Adjusting nut turned too large.
2.The air inlet blocked.
1. Continuous working too long.
2. Supply voltage not match.
3. The air inlet or outlet blocked.
4. The motor seriously worn.
Solution
1. Check power plug, socket or power
wire cord.
2. Check or replace the power switch.
3. Check and repair the motor.
4. Check or replace the motor brush.
1. Clean up or replace.
2. Check and correct the chemical
tube or tank inflatable tube.
3. Reset the chemical tube,
4. Clean up and clear the air inlet.
1. Clean up the chemical tube.
2. Correct the chemical tube.
3. Replace the chemical tube.
4. Reset the chemical tube.
1. Clean up and clear.
2. Repair or replace the motor.
1. Turn down the adjusting nut.
2. Clean up and clear.
1. Stop working for a while.
2. Select reasonable voltage.
3. Clean up and clear.
4. Repair or replace the motor.