3. Turn the Air supply on from the mains.
1
Air Inlet Port
2a
4. Lift the air regulator control knob (13) (the control knob will click securely in position), then twist
and turn the knob clockwise until roughly 2 bar of air pressure is achieved on the air gauge (19)
[3].
5. Twist and turn the air lubricator control knob (16) until roughly 1 droplet per minute is achieved [4].
NOTE: Allowing more oil than this into the motor can lead to contamination of the exhaust flow.
6. Open the Air stop/control valve (5) [2b].
7. Close the High pressure/Pressure release valve (6) clockwise.
NOTE: close valve to finger tight only.
Operating Instruction Manual:
2b
Air Valve closed
12
OM-AHP-BTU-01
Air Valve open
Serial Numbers:
FROM BQ 9522