5.3.1 Connections
Connections between couplers (see fig 5.1) are made by [1] pulling back the spring collar on the female
coupler. [2] Inserting the male coupler into the female coupler and then releasing the female spring collar.
[3] Lock the connection by (1) pushing forward on the locking-collar and then (2) twisting it clockwise and
releasing. A gentle tug on the hose should be enough to make sure the hose is correctly connected.
Disconnections are the reverse of the above process.
5.3.3. Connecting a Bolt Tensioner / Hydraulic Nut to the Pump
NOTE: For full details on how to connect a bolt tensioner/ hydraulic nut to the pump, refer to the operating
manual of the tool being used.
5.4 Filling the Air Supply Lubricant Reservoir
IMPORTANT:
The AHP-BTU Series Air Motors require ISO VG 32 (SAE10) Oil.
•
Turn Off or Disconnect from the Air Supply.
•
Remove the Air Lubricator Filler Plug (17).
•
Fill the Air Lubricator Reservoir (18) with ISO VG 32 (SAE10) Oil to the fill line marked on the
reservoir.
•
Replace the Air Lubricator Filler Plug (17).
5.5 Air Supply Requirements
•
The air supply must be delivered via a suitably rated air hose of at least 1/2" (13mm) diameter.
•
The air supply pressure must be at least 5.5 bar (80 psi), but preferably 7 bar (100 psi).
•
The compressor must be able to maintain a minimum flow rate of 50 cfm (24 l/sec).
Operating Instruction Manual:
OM-AHP-BTU-01
Fig 5.1: Hydraulic Connections
10
Serial Numbers:
FROM BQ 9522