The system operating pressure MUST NOT exceed the pressure rating of the lowest-rated
component in the system.
Good Practice:
Use a pressure gauge to monitor the entire system.
•
Only use hydraulic tools / cylinders in a complete and tested, coupled system. NEVER attempt to
use a tool / cylinder that is not correctly coupled to its operational pump.
•
NEVER pressurise an unconnected male coupler/s.
•
NEVER attempt to disconnect a hose from a hydraulic system until the system's pressure has
been completely released. Doing so can result in that pressure becoming trapped within the
system and relieving trapped pressure can be dangerous.
•
NEVER try to relieve trapped hydraulic pressure in the system by loosening or attempting to
remove the coupler. Trapped hydraulic pressure can cause a loosened coupler to dislodge
unexpectedly with great force. This action could result in serious personal injury or death.
•
Loosening a coupler under pressure can result in the escape of hydraulic oil at high pressure,
which can penetrate the skin and cause significant injury or death.
•
NEVER use a hammer and punch to unseat a coupler check valve that is under pressure. Doing
so could result in the sudden, uncontrolled release of hydraulic oil at high pressure, which could
cause significant injury or death.
•
NEVER attempt to solve, or clean-up leaks in the system while the system is pressurised.
•
Immediately replace any worn or damaged parts using genuine Hi-Force parts only.
•
DO NOT use any hydraulic equipment if you are under the influence of alcohol, drugs or
medication. Lack of attention whilst operating high-pressure hydraulic tools can result in personal
injury or death.
•
NEVER lift, carry, or move any hydraulic components by the hose or hoses connected to them.
•
Avoid damaging hydraulic hoses. ALWAYS route hoses to ensure that they are free from sharp
bends and kinks. Using a sharply bent or kinked hose will result in severe back-pressure, which
can lead to hose failure.
•
NEVER use a coupler/s to lift, carry or position a tool.
•
Servicing of hydraulic equipment must only be undertaken by a qualified technician.
•
DO NOT let familiarity gained with any hydraulic tools allow you to become complacent.
Complacency with any tooling can result in a lack of discipline toward working guidelines and
safety principles.
Failure to observe and obey the following safety precautions could result
in property damage, equipment damage or minor / moderate personal
injury;
•
DO NOT
drop or place heavy objects on a hydraulic hose, as this may
cause internal damage, which could result in rupture of the pressurised
hose. A ruptured hose could cause significant damage to components and
possible severe injury to personal operating nearby.
Operating Instruction Manual:
OM-AHP-BTU-01
4
Serial Numbers:
FROM BQ 9522